I've had this in use now for almost 6 months. Scheduling is done either in pump itself or thru an external controller such as a suntouch or easytouch controller, etc. Create an account to follow your favorite communities and start taking part in conversations. I think so. The pump was designed to always have power supplied to it, even when it is not scheduled to run. My large pliers couldn't span the union nut, so I could only tighten it hand-tight, plus about an eight turn, at most. I do like that this pool pump is quieter than the one I was using before which was on its last legs. Wiring is dirt simple. Pentair 9302C,9302S Original Instruction Manual. There are a number of cement cracks and the decking slants toward the house. Attempt to, break up impeller blockages by rotating the motor shaft through the fan cover using a hex-key. We are paying to get rid of our pool for a whole long list of reasons listed next. I had just switched out my Nautilus FNS 48 DE filter elements and put in the required DE powder. I went to Starbucks and purchased my usual coffee drink, a zebra, grandi, lava hot, 5 an 5 pumps and drove home. Check for a voltage drop when the motor is running on high speed. When the motor is stopped it is not drawing much current. Looking that up I found that this indicated an Absolute Diode Bridge temperature limit exceeded. It may not display this or other websites correctly. If so, disassemble pump. That's probably a good way to deal with most error codes on the Pentax pump. And, if you buy the extended warranty, you MUST get a pool company/pro to install it for you (which I did). Have a manual for
I refuse to pay the local pool company an extra $800 for 3 hours installation, even if I sacrifice the warranty to save the money. Or if the leak is on the front the replace O-Rings #10 or #23 in diagram.
Clean the glass with the tool provided on the front door. I tried hard resetting and turning off power for multiple minutes. Document Details: 12 pages, 1.05 MB filesize. An expert who has achieved level 3 by getting 1000 points. As I'm off the grid that is important. If you decide to buy this pump get it installed by the pool people because apparently the pump has no real warrantee and can't stand on its own, only the work you pay to have it installed does. Would I pay $600+ for it without a rebate? This pump is significantly more expensive. My mistake was to allow part of that plastic to also cover the pool pump rear fan. I read reports that this can get clogged with debris. 19 Motor Start Failure: Could indicate a locked rotor. This seems to have cleared the communication issue. operationally my pool is clear and have not had any issues with the pump. Our local utility company (PNM) was offering a rebate of $300 on variable speed/energy saving pumps, so was glad to get that.
The wiring is right.
The top section can be lifted up so the filter can be lifted out of the bottom half. Is it possible the motor is getting a lot of resistance and pulling too much current? I think the only thing I'd say would make it better? that pump impeller is correctly installed. You must log in or register to reply here. My local pool company said they would install for $140. Ensure that the 5 pin connector is properly plugged into. Basically plug and play at every point. Retailer got the pump here is good time. Direct 220 line from breaker to pump. Cost was less than $800 for the pump, plus about $40 for PVC glue, cleaner, primer, various PVC joints and fittings. Thanks!
On start, the pump does a soft-start ramp up to max speed for priming, 5 min, then it goes into a programmed routine for the rest of the day. When I put the top filter shell down in place and clamped the top and bottom assembly together it leaked. This seems to have cleared the communication issue. After power is reconnected if one of these errors continues to reappear, the drive may, VS Variable Speed Pump Installation and Users Guide, Communication Link between the HMI and Motor control has been lost, : If this error displays multiple times, then there may be a problem, : This indicates that the supply voltage has dropped below the, These errors can occur based on operating conditions, Communication link between HMI and motor control has been lost, Absolute Diode Bridge temperature limit exceeded, Absolute Power Module temperature limit exceeded, Absolute Power Factor Correction (PFC) temperature limit exceeded. I fixed the problem but ever since I have put a plastic sheet up to protect the motor from getting wet from the filter. I think they did this to hide the fact that there was a lawsuit against the company that applied the cement decking. The pump can tell what the voltage is and adjusts things internally. Required fields are marked *. on
Ensure proper pool water level and water is available to the skimmer. Thanks! I bought the pump to try and get my power bill down. This wasn't a direct PVC connection replacement, but very close. 02 Power Module Over Current Detected: If this error displays multiple times, then there may be a problem with the, pump's rotating assembly.
I love my Pentair Superflo VS Pool Pump. And the five-minute prime when it first turns on is as loud as my old pump. Pentair D65-16AVD Instructions And Service Manual. The new pipes must be installed so that when the pump is put into position, the unions are in exactly the right place to screw into the pump. It also analyzed reviews to verify trustworthiness. This may be the problem you are experiencing. If the error has not cleared then proper troubleshooting will be. Hope this analysis on my cost and installation experience helps.
Years ago I had a problem getting my DE filter top section to fit properly. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. To calculate the overall star rating and percentage breakdown by star, we dont use a simple average. I bought the Pentair VS Pump to replace a single speed pump. Runs perfectly, programs well, quiet, strong. 21 Communication Link between the HMI and Motor Control has been lost: Remove the top cover from the drive, and inspect the jacketed wire on the backside of the keypad. Possible reasons for the slow demise and ruin of the Republican Party. Then lost power last night for 8 hours. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. Posted by
02 - Absolute Phase current limit exceeded. Ensure the strainer pot lid is sealing properly. Are you checking the pump voltage when it is running? required. This was by far the easiest pump installation of them all; the pump determines all aspects of polarity, voltage and frequency. But then they said to do so, I must pay them $1500 for the pump! I hate my pool! I am using an external timer with the cable that can be found online to keep the pump running when the temperatures dip. Otherwise there could be excess voltage drops. Oh well, it was an easy pump to install. Yes, I would. Please consider. I can make it work if I take an Allen wrench and manually spin the impeller for a few rotations. Workaround :
Electrical hookup was easy. This newest one is quiet, efficient (160 watts at 1200rpm 220volt hookup) and the self timer makes it almost plug and play.
Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them. You should see all the lights light up and the screen will go into reboot and display the model and whatnot. I don't know about anyone else but paying $800.00 for a pump only to have it last 8 months is a ridiculous purchase of which I won't repeat. What I don't like is the warranty from Pentair is pretty poor. Tell us some more! If the error continues to appear after power is. Your email address will not be published.
The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. The pump has a built-in on/off switch with soft-start (very nice). Press J to jump to the feed. It ran for about 10 seconds before it started smoking in the basket area. I left the wires in my power box unchanged, but since the pump requires power 24/7, I simply removed the time-off lug nut from the timer. I hope it saves money on electricity like it is supposed to. JavaScript is disabled. Canon USA, Inc. Systems & Technical Support Division, These pumps should not be hooked into an intermatic mechanical timer. If leak is on the back of the housing - shaft seal. It just says prime then sort of clicks and flashes error 0019. https://www.troublefreepool.com/threads/pentair-superflo-vs-err-0021-plus-water.164075/, Try this. I f pushing the mode button does not work ,most likely is a bad touch pad. Improvement over my old pump in power, efficiency and quietness. Feeding the wires through a 90 degree elbow (not part of unit) into the units port proved difficult as the port is somewhat narrow yet deep. 1A,17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the required, self-diagnostic safety software. See page 13 Pump Disassembly for instructions for disassembling the pump. reconnected, proper troubleshooting will be required. Use the error description table below to begin troubleshooting. You never allow decking to slant toward a house. Document Details: 20 pages, 1.12 MB filesize. I am running it on the default setting (2hrs at 3000 rpm, 10 hours at 1400 rpm, and 2 hrs at 2200 rpm; operating from 8am-10pm). Prior to us buying this house, the former owner applied pebble stone all around the pool. Improved H1; July 11, 2022, Your email address will not be published. Reviewed in the United States on July 28, 2020. sun touch is kinda outdated you should chek out the new easy touch lite set up its a econimical way to up grade and it will give you more user friendly features, Btw, Im available to help over the phone in case u need at https://www.6ya.com/expert/kevin_7b506228149c3829. So bottom line is that they want $1,640 to install a pump that I can buy for less than $800. Very nice. The second and third speeds are really quiet; the high speed is not quite as loud as my old pump on high - but it's not too much quieter than that was. Even at its high rpms, the unit was drastically quieter than the previous pump. My local pool supplier wanted $1200+ for a variable speed pump not including install. operating range of 99v.
In other words, the 3-year warranty costs as much as a new pump. Since my old pump was 220 volt, I simply unhooked the 3 wires into the pump (two 120 volt, one ground) and re-hooked them to the new pump. 2.5" lines, short, with all angles being sweeps, and few 90's. Verify lid o-ring is in. I checked voltage at the pump and I am getting 230V consistently. Inspect suction line plumbing and valve(s) for damage or loose, 2. I certainly did as good a job as 90% of the pros would do. Would I recommend it? Add.
Otherwise there. Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. Jean Kim
Improper voltage or supply voltage. If you're in an area that might freeze, you have to winterize your pool. Thanks! The drive and timer still ticking along nicely. Pentair Intelliflo 4x160 Pool Vs-3050 Pump - If you need clarification, ask it in the. As far as I can tell it has the same inlet/outlet locations as my old Hayward. to have a valve to bleed the air out.
My father was an electrician, and later an Electrical Engineer, so I grew up learning quite a bit about electricity and electronics. After 5 years of "abuse" the bearings simply started sounding like they were giving up. Note that the rebate offered by the manufacturer is only good if you buy it at a brick-and-mortar store - not online. That's probably a good way to deal with most error codes on the Pentax pump. One comment - the pump had a sticker that said the unions should be tightened hand-tight, plus one turn. Pentair Pool & Spa? Reviewed in the United States on November 12, 2021. could be excess voltage sag caused by improper installation or improper supply voltage. Now the bottom line: I gave up the 3-year Pentair warranty by self-installation. I reread the instructions and added water. Haven't had any other issues so far. Pentair was a great pump while it worked. Verify the fan at the rear of the motor is free of debris. Disconnect power to the pump and wait until the keypad LEDs have all turned, off. I moved the plastic sheet away from the pool motor fan. Product arrived in perfect condition. Being off the grid, 1 hour from the nearest town, what pool guy is going to come out and install it? Check that pump is spinning by looking at fan on back, of SuperFlo VS Variable Speed Pump. Pentair 9306C,9306S Original Instruction Manual. socket and that there is no damage to the cable. Communication link between HMI and motor control has been lost, Absolute Diode Bridge temperature limit exceeded, Absolute Power Module temperature limit exceeded, Absolute Power Factor Correction (PFC) temperature limit exceeded, Ensure fan at the rear of pump is spinning. The pool had a diving board at one end so that end of the pool is very deep. Estimated cost is just under $20,000. Includes o-ring based pipe connectors that mate with 1.5" pipe which gives you a great seal. The email address entered is already associated to an account. The negative here and that's a BIG deal is that there is NO provision for freeze protection. Complete. An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard. Overall, a Very good deal in a pool pump. Automatically senses voltage. This is the second of these I've installed. Disassemble the pump (see Pump Disassembly on page 15) and inspect the impeller and, 0F Absolute AC Under Voltage Detected: Indicates that the supply voltage has dropped below the operating range of, 99v. I still don't know what the error means, so when I hear back from pentair I'll post it here so future people can find it. the impeller or mechanical seal. I ditched my 24 hour time and an outdoor switch when I installed this pump. Yes - if there was a rebate involved. Product : imageRUNNER C2880 / C3380 / C2880i / C3380i
This means the motor was getting too hot. Reviewed in the United States on June 16, 2017. Disconnect power at the circuit breaker long enough for the keypad LEDs to turn off. You should see all the lights light up and the screen will go into reboot and display the model and whatnot. It takes a bit of reading the manual to get it programmed right, but I think I've got it now. After that see if it comes on by pressing start. Disconnect main power by turning off the breaker long enough for the, keypad LEDs to turn off. If they do not clear after multiple restart attempts the drive should undergo a hard power, cycle. It is being practiced by thousands of pool owners just like you. Disabling it will result in some disabled or missing features. Don't think so - there are other options out there that are half the cost, including two speed pumps (but not rebate qualifiers). berkeley (17 pages), Submersible solids handling pumps (25 pages), Submersible solids handling pumps, used in hazardous locations class i, division 1 (32 pages), Submersible solids handling pumps (17 pages), Manual will be automatically added to "My Manuals", Water Pump Pentair SuperFlo VS Installation Manual, Water Pump Pentair SUPERFLO Installation And User Manual, Water Pump Pentair Flotec SUB 3S Use And Maintenance Manual, Water Pump Pentair MYERS S33 Installation And Service Manual, Water Pump Pentair SPD50H Installation And Service Manual, Water Pump Pentair hydromatic SK75/100 Installation And Operator's Manual, Water Pump Pentair SN Series Owner's Manual, Water Pump Pentair Sta-rite INTELLIPRO Installation And User Manual, Water Pump Pentair Berkeley SS1XN-1/2 Owner's Manual, Water Pump Pentair HYDROMATIC S4T Installation And Service Manual, Water Pump Pentair Hydromatic S4BX Installation And Service Manual, Water Pump Pentair HYDROMATIC S4L Installation And Service Manual, Water Pump Pentair STA-RITE SUPERMAX Hardware Installation And User's Manual, Water Pump Pentair JUNG PUMPEN SIMER 5 Instruction Manual. It is very hard on the drive of this pump, it does not like it, and will shorten the life of the drive. Not bad. Hold down the 1 button and the plus and minus button at the same time for about 5 seconds. (Pump Disassembly, page 15) and ensure impeller is correctly installed. They only give the 3-year warranty with a professional installer. Ooops. Our old pump didn't need us to. Pretty impressive. We are a registered 501(c)3 non-profit that is funded by user donations.
I applied power to the pool pump and it came back up working. Now the timer is still running, but never turns the pump off. For a better experience, please enable JavaScript in your browser before proceeding. You are using an out of date browser. The pool motor is next to the filter. I've installed several pool pumps in my life (I live in Florida and have had 4 pools in over 30 years). Then they charge $110 just to come out and look at it looked for 5 minutes and said you'll have to buy a new one? That's probably a good way to deal with most error codes on the Pentax pump. I went to turn it on and didn't add water. Your answer needs to include more details to help people.
Or with the $800 I saved, I can buy a new pump. The first was purchased in 2017 and lasted through a lot of mishandling such as running it dry, let it freeze over, and a pool that had deteriorated to the point it was no longer usable. Pentair Superflo VS Pool Pump Error Code 0008. Reviewed in the United States on October 5, 2018. You can't post answers that contain an email address. This could be caused by normal voltage variation and will clear itself. What could be the issue here? I think it's a rip-off from the local pool company to charge $1500 for a pump that they can probably order for less than the $780 I paid. Very cool operation. This could be caused by normal voltage variation and will clear itself. I had pump running 24/7 due to freeze. The pump has adjustable speed with 3 (or 4) time durations. I waited for the season to end before writing my review.
I then shut down the power to the pool pump but the pump display still was showing that I had power. - Better answers use proper spelling and grammar. Just connect two electrical wires (230V or 115V).
This seems to have cleared the communication issue. Hopefully will warm up soon and I can reset. If you can replace a light switch and an electrical outlet in you home, you can probably wire in this pump. Programming is easy as well. I get it out, anyway, but you get wet doing it. with the pumps rotating assembly. Jun 23, 2019, Try this. The pump worked great but the customer service was zero. I was trying to stick with Pentair 2-speed pump, but I couldn't find one, though web-sites are still listing them. Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. I do all the pool maintenance and I see no reasonable positive payback for the effort. Reviewed in the United States on September 7, 2017. What would be the cause of that? If this does not work the. A little tricky, but not impossible. I have same code. We bought online in January and the panel stopped working 8 months later, you only get a 60 day warrantee if you install yourself. But I saved enough money to buy a new pump, if this one should fail. When you have it wired into a timer like intermatic, power is interupted to the pump every day when the timer setting is for off. No problem, it didn't leak.
If an alarm is triggered the drives LCD screen will display the fault code text and the SuperFlo, Speed Pump will stop running. Very nice pump, very nice controls. When I opened it, there was a black dust. Try this. Quiet, powerful, easy to use/install, and impressive, Reviewed in the United States on May 11, 2020. Somewhat more difficult is the PVC piping. If so, check. In this case cleaning the Dust Proof Glass fixed the error.Check the Dust Proof Glass for soiling.The glass is located under each unit and may have toner spilled on it. The plumbing is right. Easy to install with the exception of wiring port/hole. Saves a lot of electricity.