Spectroscopy, Elemental & Isotope Analysis, Preclinical to Companion Diagnostic Development, Microbiological Media and Media Additives, Gel Electrophoresis Equipment and Supplies, Fluorescence Microscopy Reagents & Assays, High-Content Screening (HCS) and High-Content Analysis (HCA), Find scientific publications for EVOS Systems, BioProbes Journal of Cell Biology Applications, Onstage incubator with environmental control. Image is provided to Thermo Fisher Scientific courtesy of M. Sauer and L. Behringer-Plie, Biocenter University Wuerzburg. The Thermo Scientific Varioskan LUX Multimode Microplate Reader is designed specifically for bioscience researchers with a wide variety of needs and assay requirements. Our dedicated and multimode plate readers, run by powerful and intuitive SkanIt Software, provide flexibility, performance and ease-of-use in measuring absorbance, fluorescence, luminescence, time-resolved fluorescence or AlphaScreen assays. EVOS M5000 Perfect for multichannel fluorescence imaging and transfections, EVOS M7000 Perfect for a variety of advanced automated applications. attune cytometer nxt invitrogen thermofisher cytometers thermo Download the free coloring book that helps inspire your creative scientific expression. Control focus, zoom, pan, even stage movement through software. Live HeLa cells labeled with Tubulin Tracker Deep Red and NucBlue Live ReadyProbes Reagent, enabling visualization of the microtubule cytoskeleton and nuclei in live cells, respectively. See product selection guide. Combine powerful Invitrogen imaging and detection reagents with EVOS Cell Imaging Systems, Thermo Scientific Microplate Readers, and CellInsight High Content Analysis platforms. With the Celleste Image Analysis Software option, automatically quantify and analyze cellular images. (B) Cells in the non-illuminated area show viable cell growth into the wound. Thermo Fisher Scientific, Don't have an account ? Practical Tips for Cellular Quantification and Imaging Using Thermo Scientific Varioskan LUX Multimode Reader and Invitrogen EVOS FL Auto Cell Imaging System. Whether you are new to cell imaging or an experienced researcher wanting to confirm your knowledge, consider these five proven steps to help ensure that your live-cell images are publication-ready the first time. These media and wash buffers are created specifically for live-cell imaging and detection. Search Many microscopes have autofocusing features that can help keep your target in focus longer and reduce focal drift. Le systme dtanchit par hybridation HybriWell est une combinaison de lamelles et de joints qui forme des chambres optimises pour les travaux dhybridation in situ. Four-plex image of COS7 live cell. Increased dynamic range with CCD imaging. These imaging instruments and microplate readers have the option for environmental control features for extended experimental protocols using live cellstogether they can tell you a more complete biological story. Antifade mounting media for live cells can be applied to samples to reduce photobleaching of fluorophores, preventing signal loss with multiple or long exposures. Use the selection guide below to find a system that fits you. Some robust immortalized cell lines will tolerate being imaged or monitored for short periods of time without any environmental control. Improvements in chip design have enabled the development of sensitive, cooled-CCD-based cameras with higher light-capturing performance than X-ray film. HeLa cells labeled using NucBlue Live ReadyProbes Reagent, Tubulin Tracker Green dye, and Invitrogen LysoTracker Deep Red dye show superb multiplexing capability and staining specificity. Requirements vary depending on what experimental question you are asking. Thermo Fisher Scientific. This will minimize the time the sample is exposed to light. The cameras in iBright Imaging Systems and other equivalent 16-bit CCD-based imaging systems, display at least a 4-fold dynamic range, permitting the capture of strong chemiluminescent signals without sacrificing the detection of faint bands. For photobleach protection, cells were incubated with ProLong Live Antifade Reagent for 90 minutes before imaging on an EVOS cell imaging system. Image was taken with an ELYRA S.1 microscope using Structured Illumination Microscopy (SIM). Not for use in diagnostic procedures. Live HeLa cells labeled with Tubulin Tracker Green dye and Tubulin Tracker Deep Red dye. Search Cells were imaged in Gibco HBSS buffer containing calcium and magnesium, supplemented with 1X Probenecid solution. Chemiluminescent signals can easily be saturated on film due to the limited dynamic range. Chaque chambre dincubation jetable est solidement fixe sur la lame de microscope, offrant ainsi une chambre un volume limit Les lamelles pour hybridation HybriSlip sont exemptes de nuclase, prtes lemploi et spcifiquement conues pour lhybridation in situ. To minimize phototoxicity, choose imaging systems that give you the greatest control of light sources. 3,1mgapixels, couleur, 2048x 1536pixels, 1/2po. Cells were imaged in Gibco HBSS buffer containing calcium and magnesium, supplemented with 1X Probenecid solution. Avoid using autofocus for every image taken during time-lapse imaging. The Countess 3 Automated Cell Counter is a benchtop cell counting system equipped with an advanced machine-learning algorithm, ruggedized optics, fully-automated focus and lighting, and image analysis software for rapid assessment of primary and immortalized cell samples Accurateeliminates the Loutil de retrait lamelle est destin tre utilis avec une lamelle compartimente CultureWell pour culture cellulaire (n Rf. Data gathered from longer-term imaging studies are the basis of quantitative analysis studies, especially when combined with Thermo Scientific HCS Studio Software for increased statistical power. Images were generated using an EVOS FL Auto 2 Imaging System with an Olympus 60X Super Apochromat Oil objective using DAPI, GFP, and Cy5 EVOS light cubes. Ces lamelles hydrophobes ne ncessitent pas de longues procdures de prparation ou de blocage pour empcher le pigeage ou la liaison de la sonde. Create Account. Three-plex image of COS7 live cell. Don't have an account ? materials science software maps brochure Images were generated using an EVOS FL Auto 2 Imaging System with an Olympus 20X Super Apochromat objective using GFP and Texas Red EVOS light cubes. These units combine all features of a digital inverted microscope workstation into a single, compact device that can be mastered in minutes. Follow time-lapse imaging of your biofilm development using the EVOS FL Auto 2 Imaging System with the EVOS Onstage Incubator. HeLa lysates were serially diluted, transferred to nitrocellulose membrane and probed for cyclophilin B, -tubulin or DDX3. Staining must be optimized for the particular assay readout, spectral compatibility, and signal-to-background ratio. HeLa cells labeled using Invitrogen Tubulin Tracker Green dye and Invitrogen MitoTracker Red CMXRos dye show superb multiplexing capability and uniformity of staining compared with overexpressed fluorescent protein fusions. Cells were imaged in Gibco HBSS buffer containing calcium and magnesium, supplemented with 1X Probenecid solution. HeLa cells labeled using NucBlue Live ReadyProbes Reagent, ER-Tracker Green, and Tubulin Tracker Deep Red show superb multiplexing capability and uniformity of staining compared with overexpressed fluorescent protein fusions. Figure 2. Cells were imaged in Gibco HBSS buffer containing calcium and magnesium, supplemented with 1X Probenecid solution. Chemiluminescent western blotting continues to be a fundamental application to characterize proteins. Cet outil vous permet de sparer facilement la structure suprieure compartimente du verre de protection sans avoir recours une force excessive, La chambre cellules Attofluor est un porte-lamelles rsistant et pratique conu pour visualiser des chantillons de cellules vivantes sur des microscopes verticaux ou inverss. Recent advances in fluorescent dye development and imaging technology have resulted in the widespread adoption of using live-cell imaging in many diverse areas, such as developmental and stem cell biology, medical research, drug discovery, and environmental studies. UX DATA-TRKR Retired - Admins, feel free to remove this reference component. Four-plex image of U2OS live cells. CCD camera-based instruments have an increased linear dynamic range compared to X-ray film (which has 1.5 orders of dynamic range). HeLa cells were transduced with Invitrogen CellLight Mitochondria-RFP red dye and CellLight Talin-GFP green dye for 24 hours, then labeled with Invitrogen NucBlue Live ReadyProbes Reagent-Hoechst 33342 for 15 minutes. You can improve image clarity, reduce background fluorescence, and optimize cell viability by using media and wash buffers created specifically for live-cell imaging and detection. Saturation is indicated in red. Maintenant, en rponse aux demandes des clients, nous proposons des microbilles FocalCheck pr-montes sur lames de microscope. Additional fluorophores can be used to monitor multiple cellular structures and processes, but the excitation and emission spectra should be checked using the Fluorescence SpectraViewer to ensure minimal spectra overlap. Select an all-in-one transmitted light system to fit in your cell culture hood, or an automated fluorescence system with an onstage incubator, plate scanning, image stitching, and integrated analysis. Image was captured on an EVOS FL Auto 2 Imaging System using a 60X Apo objective and DAPI, GFP and RFP LED light cubes. By contrast, the bottom cell remains relatively healthy and is not displaying aberrant morphology. Whether youre capturing exquisite images for publication or counting cells for viability determination, these systems are designed to be easier, smarter, and faster. Tubulin is labeled with Tubulin Tracker Green dye, plasma membrane is labeled with CellMask Orange dye, and nucleus is stained blue with Hoechst 33342 reagent . Leverage our experience to enable your success and avoid costly wrong turns. Simplify western blot and gel data capture and analysis with our iBright Imaging Systems. Images were generated using an EVOS FL Auto 2 Imaging System with an Olympus 60X Super Apochromat Oil objective> using DAPI, GFP, RFP, and Cy5 EVOS light cubes. The use of an antifade reagent has been shown to increase fluorophore photostability and decrease the effect of phototoxicity in a variety of sample types. Dont wait! For short-term imaging experiments, use a large volume of imaging medium to prevent changes in osmolarity and oxygen resulting from evaporation of the medium. Don't have an account ? Thermo Fisher Scientific. Spend more time focused on discovery with easy to-use tools and educational materials for cell imaging, labeling, and detection. Don't have an account ? Image was taken using an ELYRA S.1 microscope using Structured Illumination Microscopy (SIM). refrigerator thermo freezer fisher scientific dotmed Thermo Fisher Scientific. Signal linearity is an important factor for quantitative measurement. This will require lower excitation power, which can correlate to lower phototoxicity and healthier cells. evos fl thermo cell imaging system microscope fisher biocompare scientific Live-cell imaging over longer periods of time can be challenging because the target may move out of focus during the course of the experiment. evos  thermofisher Cells were imaged in Gibco HBSS buffer containing calcium and magnesium, supplemented with 1X Probenecid solution. In just a few clicks, capture clear, bright, publication-quality images and videos that help you tell the story of your data. Color your way through 30 fantastic illustrations inspired by actual cell images submitted by researchers around the world. Search For Research Use Only. For Research Use Only. Tubulin is labeled with Tubulin Tracker Green dye, mitochondria are labeled with MitoTracker Orange dye, plasma membrane is labeled with CellMask Deep Red dye, and nuclei are stained blue with Hoechst 33342 reagent. HeLa cells labeled using NucBlue Live ReadyProbes Reagent, Tubulin Tracker Green, and CellLight Mitochondria-RFP show superb multiplexing capability and staining specificity. Easy to learn and affordable, EVOS systems are designed to eliminate the complexities of high-end microscopy without compromising performance. Thermo Scientific CL-XPosure Film is an excellent photographic film for use with enhanced chemiluminescence (ECL) substrates for horseradish peroxidase (HRP) or alkaline phosphatase (AP). A scratch wound in a culture of HDFn cells loaded with Invitrogen CellTracker Deep Red Dye. To avoid the pitfall of proceeding to the next step in your experiment with unhealthy cells, a quick check for cell health can be done on the Countess II FL Automated Cell Counter when used in conjunction with a variety of fluorescent reagents to detect cell viability, apoptosis, cytotoxicity, and transfection efficiency. Find the right imaging and detection tools for your research, Spectroscopy, Elemental & Isotope Analysis, Preclinical to Companion Diagnostic Development, Microbiological Media and Media Additives, Gel Electrophoresis Equipment and Supplies, Fluorescence Microscopy Reagents & Assays, High-Content Screening (HCS) and High-Content Analysis (HCA), SARS-CoV-2 Decontamination Guidance for Thermo Fisher Scientific Instrumentation, Invitrogen imaging and detection reagents, CellInsight High Content Analysis platforms, Fluorescence Imaging and Detection Reagents, Reagents for cell viability, proliferation, and function, What is high content analysis? The Cellect also supports all consumables and reagents used by Arcturus legacy instruments. Create Account, Fluorescence Microscopy Reagents & Assays, Spectroscopy, Elemental & Isotope Analysis, Preclinical to Companion Diagnostic Development, Microbiological Media and Media Additives, Gel Electrophoresis Equipment and Supplies, Olympus 60X Super Apochromat Oil objective, Olympus 60X Super Apochromat Oil objective>, Invitrogen CellLight Mitochondria-RFP red dye, Invitrogen NucBlue Live ReadyProbes Reagent-Hoechst 33342, NucBlue Live ReadyProbes Reagent-Hoechst 33342, Nunc chamber slide system, coverglass, and glass-bottom dishes, ReadyProbes Cell Viability Imaging Kit, Blue/Green, ReadyProbes Cell Viability Imaging Kit, Blue/Red, Premo Autophagy Tandem Sensor RFP-GFP-LC3B (Au), pHrodo Green Zymosan Bioparticles Conjugate (P), pHrodo Green E. coli Bioparticles Conjugate (P), pHrodo Green S. aureus Bioparticles Conjugate (P), Transferrin from Human Serum, Alexa Fluor 488 Conjugate (E), pHrodo iFL Green Microscale Protein Labeling (P/E), Zenon pHrodo iFL Green Human IgG Labeling (E), Zenon pHrodo iFL Green Mouse IgG Labeling (E), pHrodo iFL Green Microscale Protein Labeling Kit, Zenon pHrodo iFL Green Human IgG Labeling Reagent, Zenon pHrodo iFL Green Mouse IgG Labeling Reagent, Click-iT Plus EdU Alexa Fluor 488 Imaging Kit, pHrodo Red Zymosan Bioparticles Conjugate (P), pHrodo Red E. coli Bioparticles Conjugate (P), pHrodo Red S. aureus Bioparticles Conjugate (P), Transferrin from Human Serum, Alexa Fluor 555 Conjugate (E), pHrodo Red Epidermal Growth Factor Conjugate (E), pHrodo iFL Red Microscale Protein Labeling (P/E), Zenon pHrodo iFL Red Mouse IgG Labeling (E), Zenon pHrodo iFL Red Human IgG Labeling (E), pHrodo Red Epidermal Growth Factor Conjugate, pHrodo iFL Red Microscale Protein Labeling Kit, SiteClick Antibody Azido Modification Kit, Click-iT pHrodo iFL Red sDIBO Alkyne for Antibody Labeling, Zenon pHrodo iFL Red Human IgG Labeling Reagent, Zenon pHrodo iFL Red Mouse IgG Labeling Reagent, Click-iT Plus EdU Alexa Fluor 555 Imaging Kit, Transferrin from Human Serum, Alexa Fluor 594 Conjugate (E), Click-iT Plus EdU Alexa Fluor 594 Imaging Kit, Transferrin from Human Serum, Alexa Fluor 647 Conjugate (E), pHrodo Deep Red Mammalian and Bacterial Cell Labeling Kit, pHrodo Deep Red E. coli BioParticles Conjugate for Phagocytosis, Click-iT Plus EdU Alexa Fluor 647 Imaging Kit, EVOS imaging systems with onstage incubator, CellInsight high-content analysis platforms with onstage incubator, Molecular Probes School of Fluorescence: imaging basics, Thermo Scientific Nunc cell culture vessels with Nunclon Delta surface treatment, Gibco extracellular matrices, scaffolds, and proteins, Invitrogen Countess II FL Automated Cell Counter, Invitrogen BackDrop Background Suppressor, Invitrogen CellLight Mitochondria-RFP reagent, Invitrogen EVOS M5000 Imaging System with EVOS Onstage Incubator, CellInsight CX7 LZR High-Content Screening Platform with HCA Onstage Incubator, Thermo Scientific CellInsight HCA platforms, Thermo Scientific Varioskan LUX Multimode Microplate Reader, Varioskan LUX Multimode Microplate Reader, Free beautiful science cell image coloring book, BioProbes Journal of Cell Biology Applications, Observe dynamic cellular processes as they happen, Study and image several processes and functions simultaneously using multiplexed assays, Study cellular structures in their native environment, resulting in more realistic results closer to in vivo scenarios, Track cellular biomolecules and structures over time, Cellular enzymes and other cytosolic biomolecules remain in the cell, Must have a specific way to label your target with minimal toxicity whether it is a molecule, a cellular function, or a cellular state, Living cells are generally not permeable to large detection molecules such as antibodies, Moving objects can be more difficult to keep in focus, Certain techniques can be harmful to living cells, Cells must be kept in their natural physiological state, Nonspecific staining with increased background signals, Physiological artifacts and structural perturbations, Live-cell structure reagentshelp identify cellular components, Live-cell function reagentshelp identify cellular functions and processes. It is critical to avoid using too much fluorescent label because excessive fluorescent labeling can result in: Signal-to-background ratio can be optimized by using reagents that reduce extracellular fluorescence and increase fluorophore photostability. For Research Use Only. Thermo Fisher Scientific. Whether you are new to live-cell imaging or you are an experienced researcher, this webinar will show you how to obtain publication-quality live-cell images every time while avoiding the frustration of wasted time and resources. However, today CCD (charged-coupled device) camera-based imaging instruments are rapidly replacing X-ray film. Explore educational resources like the Cell Analysis Learning Center and Molecular Probes School of Fluorescence to learn how to design and optimize your experiments to get publication-quality data. In all experiments, strong signals quickly reached a plateau when detected with film. Designed to eliminate the complexities of microscopy without compromising performance, Invitrogen EVOS cell imaging systems make cell imaging accessible to almost every lab and budget. Images were generated using an EVOS FL Auto 2 Imaging System with an Olympus 60X Super Apochromat Oil objective using DAPI, GFP, and Cy5 EVOS light cubes. Create Account, Spectroscopy, Elemental & Isotope Analysis, Preclinical to Companion Diagnostic Development, Microbiological Media and Media Additives, Gel Electrophoresis Equipment and Supplies, Fluorescence Microscopy Reagents & Assays, High-Content Screening (HCS) and High-Content Analysis (HCA), Thermo Scientific high-content platforms and analysis tools, Varioskan LUX Multimode Microplate Reader, Integrated gas control for live-cell analysis, Exploration of microbial communities using the Thermo Scientific Varioskan LUX multimode reader and the Invitrogen EVOS FL Cell Imaging System, Quantitation of proliferating cells with the EVOS FL Auto Imaging System, Using time-lapse imaging with the EVOS FL Auto Imaging System, Elucidating the mechanism of cell death through the use of high-content analysis, Oxidative stress measurements made easy: CellROX Reagents with simple workflow for high-content imaging, Automated Imaging and High-Content Analysis Brochure, Determination of antioxidant capacity on the Thermo Scientific Varioskan LUX multimode reader, GPCR induction followed by a fluorometric Ca2+ assay in the Thermo Scientific Varioskan LUX multimode reader, Performing cyclic AMP hTRF screening assays with the Thermo Scientific Varioskan LUX multimode reader, Varioskan LUX Multimode Microplate Reader brochure. Thermo Fisher Scientific. Count cells, measure cell viability and monitor fluorescent protein expressionno slides or tips to buy. Smart Exposure provides an optimal image without the need to capture multiple images. CCD-based cameras utilize light-sensitive silicon chips that convert photons to digital signals. Removing the labeling solution and rinsing with fresh medium will reduce background fluorescence. UX DATA-TRKR Retired - Admins, feel free to remove this reference component. Using Smart Exposure, a wide range of signal is captured where only the highest load of HeLa is saturated, providing the greatest range of signal from the highest load to the lowest load in one image. Not for use in diagnostic procedures. tant donn que la chambre est en acier inox chirurgical et autoclavable, les cellules peuvent tre cultives directement Accessoires dinstruments dimagerie cellulaire, Cell and Tissue Imaging Calibration Tools and Standards, Modules pour instruments dimagerie cellulaire, 10 Megapixel color camera. Create Account. Le kit dtalonnage de lintensit des images de microscope InSpeck bleu fournit des normes de microsphre qui gnrent une srie de niveaux dintensit fluorescente bien dfinis pour la construction de courbes dtalonnage et lvaluation de la luminosit de lchantillon. Take full advantage of our comprehensive offering of western blotting reagents by pairing them with the right detection tool for your needs. The instrument simplifies measurement setup with automatic dynamic range selection, flexible wavelength selection, integrated gas control, and smart safety controls. With the Onstage Incubator option (on the M7000 or M5000), you can take time-lapse images of live-cell cultures to capture cellular dynamics within the incubator. Autofocus can increase the amount of light energy hitting the sample by as much as 10 times. Download the guideRequest reagent wheel. Search Image was taken with a Zeiss ELYRA S.1 microscope using Structured Illumination Microscopy (SIM). For Research Use Only. Designed specifically for Invitrogen EVOS imaging systems, the Invitrogen EVOS Onstage Incubator is an environmental chamber that enables precise control of temperature, humidity, and three gases for time-lapse imaging of live cells under both physiological and nonphysiological conditions. Images were generated using an EVOS FL Auto 2 Imaging System with an Olympus 20X Super Apochromat objective using DAPI, GFP, and Cy5 EVOS light cubes. Comprennent des objectifs, des supports de rcipients sur plateforme, des compteurs de cellules, etc. For photobleach protection, cells were incubated with Invitrogen ProLong Live Antifade Reagent for 90 minutes before imaging on an Invitrogen EVOS cell imaging system. Additionally, maintaining cells at a constant temperature and keeping the volume of solution in the vessel constant will help with focal drift. High resolution images were acquired using a confocal system. The Varioskan LUX Multimode Microplate Reader comes equipped with a flexible range of measuring technologies including absorbance, fluorescence intensity, luminescence, AlphaScreen technology, and time-resolved fluorescence. Conversely, for long-term imaging and detection studies, good results with both immortalized cells and primary cells typically require tightly controlled environmental parameters. Image is provided to Thermo Fisher Scientific courtesy of M. Sauer and L. Behringer-Plie, Biocenter University Wuerzburg. Powerful high-resolution cooled-CCD cameras in instruments such as the iBright Imaging Systems enable capture and analysis of western blots with greater signal sensitivity, linearity and dynamic range than X-ray film. EVOS microscopes are exceptionally versatile and ideal for a broad range of imaging applications, delivering superb images and data in no time, over time, every time at an exceptional value. Don't have an account ? The overall signal protection offered by ProLong Live reagentcompared to untreated samples is calculated based on the scan number where treated and untreated samples reach the EC50 value. Use the illumination that gives you the highest signal with the lowest level of fluorophore excitation. Includes an array of tools such as Z-stacking, which helps you automatically assemble images from different focal planes into a single, optimally focused image. Instruments, produits damlioration, logiciels, consommables, accessoires et autres fournitures pour la capture dimages dchantillons cellulaires pour des applications cliniques, de recherche et de laboratoire usage gnral. Chambre de cellules pour systme dimagerie, Kit de clarification/coloration de culture cellulaire 3D, Kit de clarification/coloration tissulaire, Kit de support de rcipient pour systme dimagerie, Kit de tailles de microsphres fluorescentes, Kit dchantillonneur de microsphres fluorescentes, Kit dtalonnage de lintensit des images de microscope, Lame de test du microscope fluorescence, Platine universelle pour systme dimagerie, Ractif de clarification de culture cellulaire 3D, Solution dimagerie de cellules vivantes, Support de rcipient pour systme dimagerie, talon de rfrence pour la fluorescine, Chemiluminescent western blot imaging, DNA gel imaging, Protein gel imaging, Consommables en plastique de culture cellulaire, Voir les liens pour Applications et techniques, Extraction et analyse de lADN et de lARN, Recherche sur l'pigntique et l'ARNnc, Recherche pharmaceutique et dveloppement de mdicaments, Industries pharmaceutiques et biopharmaceutiques, Spectroscopie, analyse lmentaire et isotopique, Dveloppement du diagnostic prclinique au diagnostic compagnon, Consommables en plastique et matriel de laboratoire, Ractifs et kits de biologie molculaire, Colonnes et cartouches de chromatographie, Milieux microbiologiques et additifs pour milieux, quipement et fournitures pour lectrophorse sur gel, Lecteurs et accessoires pour microplaques, Informatique de laboratoire lchelle de lentreprise, OEM & Commercial SupplyLicences et offres commerciales, Certificats danalyse et de conformit, CertificationsISO du site de fabrication, Notions fondamentales en culture cellulaire Gibco, Lettres dinformation lectroniques et journaux, Plate-forme doutils et dutilitaires pour oligos, Donnes chiffres utiles pour la culture cellulaire, Gnrateur de panels de cytomtrie en flux, Outil de conversion de gels de protines, Outil Switch-to-Nunc pour les supports de culture, Calculateur de protocoles de transfection, HybriWell Hybridization Sealing System, 40 mm x 21 mm chamber, 0.15 mm deep, HybriSlip Hybridization Cover, 40 mm x 22 mm, RNase free, InSpeck Blue (350/440) Microscope Image Intensity Calibration Kit, 2.5 m, HybriSlip Hybridization Cover, 22 mm x 22 mm, RNase free, FocalCheck Thin-Ring Fluorescent Microspheres Kit, 1.0 m, three suspensions, FocalCheck Microspheres, 6 m, fluorescent green/orange/dark-red ring stains, FocalCheck Fluorescent Microspheres Kit, 6 m, mounted on slides, Countess 3 FL Automated Cell Counter Starter Package + ABRC Extended Warranty, Countess 3 Automated Cell Counter + ABRC Extended Warranty, Countess 3 FL Automated Cell Counter Starter Package + REX Extended Warranty, Countess 3 FL Automated Cell Counter + REX Extended Warranty, Chambre cellulaire Attofluor, pour microscopie, Applications de bureau et applications mobiles. Cells in this area show signs of phototoxicity (a loss of viability as cells were not able to grow into the wound). Spectroscopy, Elemental & Isotope Analysis, Preclinical to Companion Diagnostic Development, Microbiological Media and Media Additives, Gel Electrophoresis Equipment and Supplies. Addition of BackDrop Background Suppressor greatly reduces extracellular background while leaving intracellular labeling unaffected (right), thus enabling a no-wash protocol for high-contrast imaging of tubulin in live cells.